16 X 128 Fischer FAZ II Plus 16/5 R A4 Anchor Bolt 564626

16 X 128 Fischer FAZ II Plus 16/5 R A4 Anchor Bolt 564626

16 X 128 Fischer FAZ II Plus 16/5 R A4 Anchor Bolt 564626
DYTM616128FAZP
In Stock
BPIR (click to view)
Your cart has been updated.

16 X 128 Fischer FAZ II Plus 16/5 R A4 Anchor Bolt 564626

DYTM616128FAZP
In Stock
BPIR (click to view)
fischer Stainless Steel FAZ II Bolt Anchor
Your cart has been updated.
In Stock
BPIR (click to view)

Anzor Building
Product Information Sheet

{this.state.description}

Product Disclosure Information Self-Assessment
Version:
Product name-
Product line-
Product identifier-
Product description.
-
Relevant building code clauses
-
Contributions to compliance
-
Scope of use
-
Conditions of use
Items should be used as specified by a qualified engineer.
Contact details
Manufacture location-
Legal and trading name of manufacturer-
Legal and trading name of importerAnzor Fasteners Ltd
Importer address for service93 Apollo Drive, Rosedale
Auckland 0632
Importer websitewww.anzor.co.nz
Importer NZBN9429038848490
Importer emailsales@anzor.co.nz
Importer phone number09 476 0001
Warnings and bans
Is the building product/building product line subject to warning or ban under section 26 of the Building Act 2004?
No

Appendix
BPIR Selections
-
Building code performance clauses
All relevant building code performance clauses listed in this document:
-

FAZ II Plus have ETA (European technical assessment) that meets the NZBC requirements (NZS 3101 concrete structures standard).

Advantages
  • 316 stainless steel or higher
  • C1/C2 seismic rating
  • For external use with 50 Year Design Life when used as described in ETA
  • Meets BPIR regulation
  • Quick and easier assembly without the need for drill hole cleaning (M8-M24).
  • Numerous approval certificates for different substrate materials (concrete C12/15-C80/90, steel fiber concrete, solid sand-lime brick) increase the number of applications and fields of use.
  • With the new assessment (ETA), the tensile strengths increase decisively. As a result, fewer fixing points and anchors are required.
  • The new ETA confirms the use of the FAZ II Plus for dynamic loads for diameters M16-M24.
  • The fast installation process of the FAZ II Plus provides an efficient fixing solution for dynamic applications with low load cycles (M16-24) with an immediately loadable fixing point.
  • The ETA evaluation, together with other test reports (RWS, ZTV, ETK), ensures high loads in case of fire.
  • An external independent assessment confirms the service life of anchorages up to 120 years. Thus, the FAZ II Plus outlasts a whole century and is perfectly suited for large, long-lasting construction projects (M10-M16).
  • The FAZ II Plus allows the absorption of high seismic loads of performance category C1 and C2 for diameters M10-M24 with and without the use of the filling disc FFD at installation.
  • The variable anchorage depths allow a millimetre-accurate adjustment to the loads.
  • The first bolt anchor M6 with ETA evaluation option 1 ensures a safe and approved anchorage.
Applications and Approval

Applications

  • Steel constructions
  • Guard rails
  • Consoles
  • Tunnels
  • Lifts
  • Lifting platforms
  • Conveyor belts
  • Pumps
  • Ladders
  • Cable trays
  • Machines
  • Staircases
  • Façades
  • Timber constructions

Building materials

Approved for:

  • Concrete C20/25 to C50/60, cracked and non-cracked

Also suitable for:

  • Concrete C12/15 - C80/95 (classification available)
  • Steel fiber concrete (classification available)
  • Solid sand-lime brick (classification available)

You can find detailed information on building materials in the approval document.

Approval

  • ETA-19/0520
  • ETA-20/0897
  • DoP No. 0334
  • DoP No. 0337
  • 3023222
  • ESR-2948
  • BZS D 23-607
Installation
  • The FAZ II Plus is suitable for pre-positioned and push-through installation and is also ideal for stand-off installation thanks to the long thread.
  • When applying the torque, the cone bolt is pulled into the expansion sleeve and expands it against the drill hole wall.
  • The anchor is set in line with the approval once the preset installation torque is achieved.
  • In the case of series installation, we recommend using the FABS or FA-ST II anchor bolt setting tools.
  • In case of seismic demands, the annular gap can be filled using the filling disc FFD.
  • For dynamic loads, an additional "dynamic set" is used, which is filled with injection mortar (compressive strength ≥ 50 N/mm² e.g.: FIS V Plus, FIS EM Plus, FIS HB or FIS SB) after installation.
  • Visit fischer for Technical Data and Assembly Instructions.
Downloads

Zudvx7vsgrysvyjv Fischerfixperienceproductinfo

16 X 128 Fischer FAZ II Plus 16/5 R A4 Anchor Bolt 564626

16 X 128 Fischer FAZ II Plus 16/5 R A4 Anchor Bolt 564626

16 X 128 Fischer FAZ II Plus 16/5 R A4 Anchor Bolt 564626
DYTM616128FAZP
In Stock
BPIR (click to view)
Your cart has been updated.

16 X 128 Fischer FAZ II Plus 16/5 R A4 Anchor Bolt 564626

DYTM616128FAZP
In Stock
BPIR (click to view)
fischer Stainless Steel FAZ II Bolt Anchor
Your cart has been updated.
In Stock
BPIR (click to view)

Anzor Building
Product Information Sheet

{this.state.description}

Product Disclosure Information Self-Assessment
Version:
Product name-
Product line-
Product identifier-
Product description.
-
Relevant building code clauses
-
Contributions to compliance
-
Scope of use
-
Conditions of use
Items should be used as specified by a qualified engineer.
Contact details
Manufacture location-
Legal and trading name of manufacturer-
Legal and trading name of importerAnzor Fasteners Ltd
Importer address for service93 Apollo Drive, Rosedale
Auckland 0632
Importer websitewww.anzor.co.nz
Importer NZBN9429038848490
Importer emailsales@anzor.co.nz
Importer phone number09 476 0001
Warnings and bans
Is the building product/building product line subject to warning or ban under section 26 of the Building Act 2004?
No

Appendix
BPIR Selections
-
Building code performance clauses
All relevant building code performance clauses listed in this document:
-

FAZ II Plus have ETA (European technical assessment) that meets the NZBC requirements (NZS 3101 concrete structures standard).

Advantages
  • 316 stainless steel or higher
  • C1/C2 seismic rating
  • For external use with 50 Year Design Life when used as described in ETA
  • Meets BPIR regulation
  • Quick and easier assembly without the need for drill hole cleaning (M8-M24).
  • Numerous approval certificates for different substrate materials (concrete C12/15-C80/90, steel fiber concrete, solid sand-lime brick) increase the number of applications and fields of use.
  • With the new assessment (ETA), the tensile strengths increase decisively. As a result, fewer fixing points and anchors are required.
  • The new ETA confirms the use of the FAZ II Plus for dynamic loads for diameters M16-M24.
  • The fast installation process of the FAZ II Plus provides an efficient fixing solution for dynamic applications with low load cycles (M16-24) with an immediately loadable fixing point.
  • The ETA evaluation, together with other test reports (RWS, ZTV, ETK), ensures high loads in case of fire.
  • An external independent assessment confirms the service life of anchorages up to 120 years. Thus, the FAZ II Plus outlasts a whole century and is perfectly suited for large, long-lasting construction projects (M10-M16).
  • The FAZ II Plus allows the absorption of high seismic loads of performance category C1 and C2 for diameters M10-M24 with and without the use of the filling disc FFD at installation.
  • The variable anchorage depths allow a millimetre-accurate adjustment to the loads.
  • The first bolt anchor M6 with ETA evaluation option 1 ensures a safe and approved anchorage.
Applications and Approval

Applications

  • Steel constructions
  • Guard rails
  • Consoles
  • Tunnels
  • Lifts
  • Lifting platforms
  • Conveyor belts
  • Pumps
  • Ladders
  • Cable trays
  • Machines
  • Staircases
  • Façades
  • Timber constructions

Building materials

Approved for:

  • Concrete C20/25 to C50/60, cracked and non-cracked

Also suitable for:

  • Concrete C12/15 - C80/95 (classification available)
  • Steel fiber concrete (classification available)
  • Solid sand-lime brick (classification available)

You can find detailed information on building materials in the approval document.

Approval

  • ETA-19/0520
  • ETA-20/0897
  • DoP No. 0334
  • DoP No. 0337
  • 3023222
  • ESR-2948
  • BZS D 23-607
Installation
  • The FAZ II Plus is suitable for pre-positioned and push-through installation and is also ideal for stand-off installation thanks to the long thread.
  • When applying the torque, the cone bolt is pulled into the expansion sleeve and expands it against the drill hole wall.
  • The anchor is set in line with the approval once the preset installation torque is achieved.
  • In the case of series installation, we recommend using the FABS or FA-ST II anchor bolt setting tools.
  • In case of seismic demands, the annular gap can be filled using the filling disc FFD.
  • For dynamic loads, an additional "dynamic set" is used, which is filled with injection mortar (compressive strength ≥ 50 N/mm² e.g.: FIS V Plus, FIS EM Plus, FIS HB or FIS SB) after installation.
  • Visit fischer for Technical Data and Assembly Instructions.
Downloads

Zudvx7vsgrysvyjv Fischerfixperienceproductinfo

Learn Something New

To receive useful info and product updates add your details below

You are subscribed to push notifications but they are not enabled in your browser.
Please either enable push notifications here or unsubscribe here.