Tensile strength is the maximum tension applied, as loading, that a fastener can support prior to, or coincidental with, its fracture.


Thread Size Stress Area AS Tensile Load in kN as xRm*
A2-50, A4-50 A2-70 & A4-70 1)4) (304 & 316 Class 70) A4-803)4) (316 Class 80 & Bumax 88) Bumax 109
M3 5.03 2.52 3.52 4.02
M3.5 6.78 3.39 4.75 5.42
M4 8.78 4.39 6.15 7.02 8.80
M5 14.20 7.10 9.94 11.36 14.00
M6 20.10 10.05 14.07 16.08 20.00
M8 36.60 18.30 25.62 29.28 37.00
M10 58.00 29.00 40.60 46.40 58.00
M12 84.30 42.15 59.01 67.44 84.00
M14 115.00 57.50 80.50 92.00 115.00
M16 157.00 78.50 109.90 125.60 157.00
M18 192.00 96.00 134.40 153.60 192.00
M20 245.00 122.50 171.50 196.00 245.00
M22 303.00 151.50 212.1
M24 353.00 176.50 247.10 282.40 353.00
M27 459.00 229.50 321.30
M30 561.00 280.50 392.7 448.8

Note: This chart is provided as cross reference. For accurate values the actual specifications should be reviewed.

Learn Something New

To receive useful info and product updates add your details below

Anzor Wallchart

Wall Chart

Request a copy of our Engineering & Marine, or Construction Wall Chart.

Anzor Catalogues

Standard Catalogues

Click here to download a PDF of our Engineering Catalogue. This catalogue includes stainless fasteners and fittings, marine hardware and construction brackets.

Anzor Catalogues

Construction Catalogues

Click here dot download a PDF of our Construction Catalogue. This catalogue includes stainless/galvanized fasteners and fittings, and construction brackets.

You are subscribed to push notifications but they are not enabled in your browser.
Please either enable push notifications here or unsubscribe here.